BWB INSTRUMENTS

VORTEX FLOW METER

VORTEX FLOW METER

Features

  • Integrated pressure and temperature compensation for accurate steam and gas measurement
  • Output options: 4–20mA with pulse and HART, or 4–20mA with pulse and RS485
  • Wide temperature range up to 350°C for high temperature process applications
  • Embedded sensor with four piezoelectric crystals fully encapsulated inside the sensor body
  • No moving parts, no abrasion, and no wearing components inside the meter body
  • Fully welded SS304 body as standard; SS316 available as option
  • Available in compact type and remote type (converter display or flow computer display)
  • Five connection types: flange, wafer, tri-clamp, thread, and insertion

Reliable Flow Measurement for Liquid, Gas, and Steam Applications

 

The BWB Instruments Vortex Flow Meter provides accurate, reliable volumetric flow measurement for liquids, gases, and steam across a wide range of industrial process applications. Built with no moving parts and no wearing components, it delivers long-term, maintenance-free performance in demanding conditions. Particularly well suited for saturated and superheated steam measurement in power generation and heat supply systems, the meter is equally effective for compressed air, nitrogen, liquefied gases, flue gas, carbon dioxide, solvents, heat transfer oils, boiler feedwater, and condensate applications.

Available in compact and remote configurations, with connection options including flange, wafer, tri-clamp, thread, and insertion types to suit a broad range of pipe sizes and process conditions.

Benefits

  • No moving parts and no wearing components ensure long service life and minimal maintenance requirements across continuous duty applications
  • Integrated pressure and temperature compensation delivers accurate steam measurement without external instrumentation, reducing overall system complexity
  • Wide fluid compatibility covering liquid, gas, saturated steam, and superheated steam from a single meter design
  • High temperature capability up to 350°C makes it suitable for steam and thermal fluid applications in power generation and heat supply systems
  • Compact and remote configurations available, with remote type supporting converter display or flow computer display for flexible installation in restricted access locations
  • RS485 MODBUS and HART communication for direct integration with plant control and monitoring systems
  • Insertion type available for large diameter pipes up to DN2000 without full bore installation
ParameterDetails
Measured MediumLiquid, Gas, Steam
Medium Temperature-40 to +250°C standard; -40 to +350°C high temperature type
Accuracy±1.0% (flange / wafer / thread / tri-clamp); ±1.5% (insertion type)
Flow Range – Liquid0.4 – 7.0 m/s
Flow Range – Gas4.0 – 60.0 m/s
Flow Range – Steam5.0 – 70.0 m/s
Size – Flange / WaferDN15 – DN300
Size – InsertionDN80 – DN2000
Size – Thread / SanitaryDN15 – DN100
Body MaterialSS304 standard; SS316 optional
Reynolds NumberNormal 2 × 10⁴ to 7 × 10⁶
Resistance CoefficientCd ≤ 2.6
Vibration Acceleration Allowed≤ 0.2 g
Ambient Temperature-40 to +65°C / -20 to +55°C
Relative Humidity≤ 85%
Ambient Pressure86 – 106 kPa
Power SupplyDC 12–30 V or 3.6 V lithium battery
Signal Output4–20 mA, Pulse
CommunicationRS485 MODBUS or HART
Pressure – FlangeDIN PN10 / PN16 / PN25 / PN40; JIS 10K / 20K / 30K / 40K; ANSI 150# / 300#
Pressure – Wafer40 bar
Pressure – Thread / Tri-clamp / Insertion16 bar

Get the Right Meter for Your Application.

Get in touch with our team to discuss the right flow measurement solution for your process requirements.

Scroll to Top